Hydroelectric power plants face harsh conditions such as moisture presence, rocky ground, high soil resistance, and complex electrical installations that make proper earthing a challenging task.
Failure to properly design a power plant earthing system or deterioration of the existing earthing system poses electrical safety hazards, affects equipment protection, and may lead to unexpected shutdowns.

Water, moisture, and metallic installations need proper bonding and corrosion evaluation.

Rocky surfaces, varying soil conditions, and a lack of space for installing electrodes may pose difficulties for earthing in rocky soil. Earthing in difficult geologies needs a proper site evaluation before the design is finalised.

Conventional Earthing / Poor Quality Earthing
Marconite earthing uses Marconite, a conductive aggregate, in specialised industrial earthing projects. If installed correctly with the proper soil testing and designed for optimum earth resistance values, it effectively increases the conductivity of the environment surrounding the electrode.
It can be used in a hydroelectric power plant project with difficult rocky terrain, poor ground conductivity, or high moisture areas.
Intertech can handle design and execute earthing of hydroelectric plant of any size.
Wondering how it compares with chemical earthing?
Read the full comparison.

Does not corrode at all when compared to chemical earthing, hence gives consistent resistance values.

Electrical earthing for any application such as industrial buildings, commercial buildings, residential buildings, lightning protection, etc.

Maintenance-free earthing that can perform for 50+ years, backed by a 25 year warranty. Does not require water & charcoal to replenish the earth pit as in the case of chemical earthing.

Marconite earthing has the lowest life cycle cost when compared to chemical earthing.

Permanent & consistent low resistance of 0.001 Ωm

This engineered Marconite earthing compound works most effectively in the toughest soil conditions.

IS 3043 & IEC 62561-7

Does not pollute groundwater table
Intertech can provide earthing for power plant areas such as these:

Earthing and bonding for turbines, for each generator in a hydro power plant, and for the metallic structures of the powerhouse.

Transformer earthing and an earthing system in a switchyard or substation, connected to the plant earthing grid.

Earthing for control panels, communication systems and instrumentation.

Earthing support for the plant's lightning protection system, to carry lightning and surge current safely into the ground.
Conduct an analysis of the current earthing system, soil resistivity, topography, space availability at the site, etc. Read more about our earthing audit and soil testing service.
Conduct an analysis of fault current magnitude, fault duration, touch and step voltage levels, bonding, lightning protection needs, etc.
No of Marconite electrode pits and the grid system required, conductor size, connections for the application.
Install the designed earthing system and incorporate it within the plant earthing grid and associated metallic structures.
Testing of the installed earthing system and verify its performance against the design specifications and safety criteria. Review our test reports and certificates.
It provides a means to manage fault currents, control touch and step voltages, bond conductive materials, and support lightning protection.
High-resistivity soil, rocky ground, moisture-related issues, degradation of connections, corrosion, and poor bonding might result in poor earthing.
Yes. It is suitable for use in rocky soils, but only after proper site evaluation and engineering considerations.
Generators, turbines, transformers, switchgear, substations, control panels, communication systems, cable trays, and conductive structural elements of the plant require earthing or bonding.
Not necessarily. Marconite is a conductive aggregate used in appropriate electrode systems. The earthing grid, bonding, fault current paths, and lightning protection still have to be engineered.
Yes, appropriate testing is required to validate the system against its design specifications and safety criteria.
Yes, Intertech also does earthing for small and mini hydro plants.
Talk to the Earthing Experts at Intertech about your site requirements, current earthing issues, and hydroelectric power plant project needs.