Every healthcare electrical maintenance personnels wants the highest level of electrical safety for
Healthcare environments face unique electrical safety challenges that traditional earthing systems simply cannot handle effectively. Almost all healthcare facilities operate life-saving equipment round the clock like ventilators, MRI machines, ECG monitors, and emergency power systems that patients depend on for their survival.
Electrical shock risks to patients and staff during medical procedures
Equipment malfunctions causing treatment delays
Fire hazards in oxygen-rich environments
Power disruptions affecting critical care units
Regulatory compliance failures threatening accreditation
Marconite Earthing is a revolutionary conductive concrete backfill material that delivers ultra-low resistance earthing with zero maintenance requirements. Unlike traditional earthing systems that depend on water and chemicals, Marconite conducts electricity through electron movement – the same principle used in metals.
0.001 ohm-meters (Ω⋅m) (compared to 3-5 ohm-meters (Ω⋅m) for chemical earthing)
Rocky, sandy, dry, or clay conditions
No water or chemical recharging required
50+ years of consistent performance
Conductive properties of Marconite remain stable regardless of weather conditions or soil moisture levels, providing the reliable earthing for healthcare facilities.
Marconite earthing creates an ultra-safe electrical environment by rapidly conducting fault currents away from patients and equipment. The system prevents electrical shocks during procedures and protects the patients as well as the doctors. This is especially important in ICUs and operating rooms where patients are most vulnerable to electronic equipment.
Your expensive diagnostic and life-saving equipment operates in consistent, stable electrical conditions. Marconite earthing prevents equipment damage from electrical surges, reduces electromagnetic interference, and ensures accurate readings from sensitive devices.
Healthcare facilities must meet stringent electrical safety standards. Marconite earthing exceeds these requirements by a permanent & consistent low resistance for 50+ years.
While traditional earthing systems require ongoing maintenance, water recharging, and periodic replacement, Marconite provides 50+ years of maintenance-free operation. This eliminates recurring costs and reduces total expenses by up to 60% compared to chemical earthing systems.
Marconite is completely eco-friendly with no groundwater pollution or chemical leaching. The system requires no charcoal (protecting forests) and no ongoing water consumption, supporting the sustainability goals of your healthcare facility.
They were able to achieve remarkable results with Marconite earthing installation, which reduced earth resistance from 2.61Ω to 0.51Ω - an 80% improvement in safety performance. The installation has been operating with zero maintenance for over 10 years, protecting critical MRI Machine & other medical equipment.
Saral Diagnostic Centre, New Delhi experienced similar success with their Marconite earthing system. Ground resistance was less than 1Ω which helped in protecting all the critical diagnostic medical equipment like CT scan, MRI, X-Ray Machine, etc.
Marconite earthing technology has been operational in many hospitals, nursing homes, diagnostic centers, and specialty medical facilities across diverse geographic and soil conditions in India
Healthcare facility managers consistently report:
Tailored specifically, for healthcare facilities includes site assessment, soil analysis, and custom engineering solutions.
By certified technicians ensures optimal performance and compliance. We coordinate with the operations team of your facility to minimize disruption to patient care during earthing installation. rrghfrhc
We test earthing using digital earth tester and provide detailed reports showing earth resistance values before handing over the earthing system.
While Marconite earthing requires no maintenance, we provide verification testing to support your healthcare facility safety documentation requirements.
Our healthcare earthing specialists will assess your current system and demonstrate how Marconite earthing improves safety while reducing long-term costs and get ROI analysis showing cost savings over 50 years.
Permanent & consistent low resistance of 0.001 ωm
Does not corrode hence gives consistent resistance values
Maintenance-Free for 50 Years. Does not require water & charcoal to replenish earthing pit as in the case of chemical earthing
Industrial, Commercial Building, Residential Buildings, Lightening Protection, etc.
Engineered Substance – works most effectively in the Toughest Soil Conditions
Does not pollute groundwater table
Becomes compact in a few hours once installed
Marconite Earthing has lowest life cycle cost when compared to Chemical Earthing
Marconite earthing systems are guaranteed for 50+ years of maintenance-free operation. The conductive material does not degrade over time and maintains consistent low resistance values throughout its life.
Marconite offers significant advantages: ultra-low resistance (<1Ω vs 3-5Ω), zero maintenance, works in all soil conditions, and provides 50+ years of performance compared to chemical systems that require regular maintenance and replacement.
Yes, Marconite is completely safe with neutral pH (6.8-7.1), no chemical leaching, and no groundwater contamination. The material is inert and poses no health risks to patients, staff, or the environment.
Marconite earthing performs effectively in all soil types – rocky, sandy, clay, dry, or wet conditions. Unlike chemical earthing that depends on soil moisture, Marconite maintains consistent performance regardless of soil conditions.
No maintenance is required. Marconite earthing operates maintenance-free for 50+ years with no water recharging, chemical replenishment/replacement. It helps to eliminate ongoing operational costs and electrical safety risks.
Subscribe to Our Newsletter
As per our requirement and request, your company has provided the knowledge and installation of 5 nos. of maintenance free earthing stations based on Marconite (conductive concrete based earthing) at our Electron Beam Centre, Kharghar, Navi Mumbai. Out of these 5 earthing pits, 4 nos. are connected in the parallel network to achieve an earth pit resistance of 0.65Ω which is required for our HV pulse power applications. We are glad to get these maintenance free earthing stations having less than 1 ohm.
Accelerator & Pulse Power Div., BARC
We adopted Marconite Conductive Concrete technology for treated earth pits 1 X 700 MW Ballary Thermal Power Project at Ballari of Karnataka Power Corporation Ltd. The land of the project is rocky terrain. The design was approved by our engineering group PEM – Noida and the client and could be able to achieve the desired earth resistance as per client’s requirement.
Electrial & CI PSSR
Some of Our Prestigious
Intertech’s cutting-edge qualitative services have developed trustworthiness & goodwill among its clients. Marconite earthing solutions are developed to cater to…
Installations
Happy Customers
of Earthing
Solution
Channel Partners
Across India
Direct Share or Chat on Whatsapp
Enter Country Code Without (+)